QuestionHi Paul, I have a generator which starts 1st pull and runs great, however if connected to a load of 300watts or more runs fine for a minute or two and then the engine begins to cut out. i do state BEGINS because if you remove the load the engine continues to run very erratically for a min or two, coughs and bursts back to life as if nothing is wrong. i have tried bypassing the oil sensor and kill switch. fault still remains
Answerhi royston
have you had carby off and checked main jet could be blocked or restricted
running of engine with load is maintained by main jet - but check all carb pilot jets and air bleeds as well check fuel flow from tank to carb and tank breather as well
try adjusting governor as well as no aceptance of load could be governor needing adjustment too
check your valve clearance as well 0.004" inlet and 0.006" exhaust @ tdc compression stroke
check your muffler it could be restricted ?
check that all springs etc are in correct positions and are free to move
to adjust governor - raise tank , loosen clamp on governor lever holding it to gov shaft
move the throttle plate to full open and hold it there, turn the governor shaft full in a clockwise direction ( note do not force )as viewed from the pull start side on the engine
tighten the governor lever clamp
this proceedure removes any slack in the system and places the governor and spool and cup in known positions because while engine is stopped closing force is removed and throttle plate moves to full open
here is web site http://www.honda-engines-eu.com/en/welcome.html
select the model series ie gx160 type ie
type in the numbers off the cylinder block or footing
you can load and save a copy of parts lists
cheers hope it helps
paul