Questionhi i have an 11 horsepwer briggs straton engine in my portable generator its about 12 years old. latley i have not been able to idle it unless its at 3/4 choke and the vibration always runs it back to "RUN" which cuts it off. i have changes the -fuel filter-sparkplug- fuel line! cleaned the carb. changed fuel - runs great if i hold it at 3/4choke.. Paul any idea what is wrong? im lost.. thx joe
Answerhi joe
1)have you checked for a blocked muffler ,?
2)is compression ok ?
3)check for a exhaust or inlet valve leak ?
4)have you checked for for a manifold joint air leak ?
5)is spark at right time
dry compression test, record readings then ( pour into cylinder sae 30 oil tablspoon full) @ tdc compression stroke ,leave for 1 minute ,the wet compression test - record readings
if wet test compression result alot higher than dry compression test result - worn rings indicated but if wet test result no higher than dry compression test result - burnt valves or blown head gasket or tight valves indicated .
if all these are ok , then i would suspect something blocked in the carby , by closing choke to 3/4 you are making the air pressure less and letting engine vaccuum travel througout carb venturi while atmospheric air pressure forces volume of fuel from main jet and emulsion tube for startimg and engine runs ok but open choke it starts to die due to no fuel from venturi and or progression ports / idle ports
if the 5 points above check out and are fine then recheck all carb openings / etc / jets / nozzles / vents
cheers paul
ps let me know what you find , if i can help just holler