Questionhi i have a 2.6 kva mach purewave inverter generator,model number ME-GG2500LB I BROUGHT IT FROM EBAY a month ago,it was running fine for a week and then it slowly stop,i thought it was a low oil alarm that stop it ,not the case as it was full of oil.so i disconnected the oil sensor,to stop it from grounding out,still no spark,i had the coil tested it was ok,there is a small amount of power going to the coil but not enough to make a spark,is there any other censers on it?or what else can i do to get it going,thank you from jeff
Answerhi jeff
does this unit have engine that looks like a honda gx160 or gx200
unit sounds like it but cant be sure never seen type you mention ,
if you have oil sensor disconnected, and spark is poor , check plug resistor cap for excessive resistance should be no more than 5000 ohms or 5 k/ ohms - make sure circiut breaker or switch has not been tripped next check the kill wire for shorting , diconnect from ignition coil end as well spark should jump a 6 mm gap minimum , this stresses the coil and tests the reserve voltage as well if it does not do this faulty coil indicated ,but check flywheel key check flywheel magnets , check air gap at coil should be 0.010 - 0.012 thou
make sure oil in unit is of correct type , these units do not like sae 30
they usually like 20w/50 or 10w/40
cheers paul
ps let me know if honda look alike engine