Questionjust bought one at auction and brought home put some gas in it and it ran. shut it off to further clean the gas tank and wont restart! I dont think I have spark? any easy answer?
AnswerHello Reuben:
>>If the Generator has a Low Oil Sensor, then
>>Disconnect the Wires from the Sensor and Check the Plug for Fire.
>If No Fire, then
>>Disconnect the Shut Off Wires from the On/Off Switch and Make Sure they Do Not Touch Metal and Check for Fire at the Plug.
>>If No Fire at the Plug, then
>>Remove the Blower Housing (metal engine cover) and Remove the Wire from the Ign Module/Coil/Armature. Check the Plug for Fire.
>>If Still No Fire, then Replace the Ign Module/Coil/Armature.
>>You can View a Breakdown/IPL of the Mower/Engine at this Site Addy, http://hayward.arinet.com/scripts/EmpartISAPI.dll?MF&app=ASP&lang=EN&TF=Mainfram... and Select the Catalog American Honda.
>>Please, Do Not Hesitate, If you Hit a Snag, if I Missed Something or this Does Not Correct the Problem, I am Here if You Require More Assistance. Hope this Helps. Let me Know What Happens, Please. May the All Mighty Bless You and Yours. Thanks.
Good Luck
Respectfully
John
>>PS: I am Allowed to Answer 10 Questions a Day. If you See I am Maxxed Out, then Try Submitting your Question at or Just After 8pm EST (US). My New Day Starts then. Comments and Ratings are Greatly Appreciated. Thanks.
Respectfully
John